Green House Data Selects Deerns America to Design New Cloud Hosting and Colocation Facility

Green House Data has partnered with mechanical and electrical engineering firm Deerns America for both their expertise in green data center design and for their patented Green Cooling for Data Centers (GC-DC) air conditioning technology. This energy efficient data center will operate at levels 75 percent more efficient than the typical data center, according to the Uptime Institute survey in May 2011.

Set to open its doors in the first quarter of 2013, the new 25,000-sq-ft facility will utilize year round 100 percent free cooling. The air conditioning technology has been custom designed by Deerns America and when combined with the data center’s overall efficiency will allow the Green House Data facility to run at an annual average power usage effectiveness (PUE) of 1.16 and a peak PUE of 1.22.

“This progressive step is an exciting advancement for our company adding additional data center space utilizing energy efficient 100 percent free cooling,” stated Shawn Mills, president of Green House Data. “I see the increasing demand for low-energy cooling systems, green technologies and efficiencies as an avenue to reduce utility costs and offer these savings to our clients in this competitive industry.”

100 Percent Free Cooling System Design

The innovative cooling combines proven technologies in a new application that can serve up to 40 kW of IT load per rack. Within each unit, outdoor air is drawn through a plate heat exchanger where it absorbs heat from the IT room’s hot return air.  It is then cooled and re-circulated through the data center. By separating the air streams in this way, the outside air can be cooled evaporatively without influencing the humidity in the white space and without risk of contamination from dust, smoke, pollen, and other particulates. Even as outdoor air temperatures rise, evaporative coolers will provide low-energy supplemental cooling without requiring the use of refrigeration based cooling systems.

The proprietary cooling design removes the need for under floor plenums as the units can deliver cool air directly to the computer floor, which is optimal for Green House Data’s use of hot, and/or cold aisle containment. Additionally, the cooling system can seamlessly grow along with Green House Data’s modular data center building design as new units can be added as needed.

“With the cool, dry geographical location selection chosen by Green House Data, implementing our free cooling system will have a great impact on energy efficiency,” stated Gary Cudmore, principal of data center engineering for Deerns America. “Additionally, the GC-DC system we’ve developed for this project will provide a data center environment complying with ASRHAE TC 9.9 guidelines without the need for expensive, energy-intensive chillers.”

The building features include:

  • 25,000-sq-ft building (15,000 sq ft of data center white space)
  • 700 data cabinets (29,400 physical servers)
  • Tier 3 – concurrently maintainable
  • 4.5 MW – Critical IT load (5.7KW/cabinet)
  • 45% more energy efficient data center design, when compared to the typical data center.
  • Year-round free cooling
  • 100% Wind powered
You must register or login in order to post comments.

Multimedia

Videos

Image Galleries

The Adventures of Kip and Gary

Diane Alber takes a humorous view of data center operations in her comic strip Kip and Gary. In the comic strip, Kip and Gary navigate problems familiar to data center professionals. You can see more at http://kipandgary.com/blog/

11/09/11 2:00 PM EST

Part 1: The Economics of Close-Coupled Cooling in the Data Center

Mission CriticalON-DEMAND: This presentation will detail the economics involved with each solution, CAPEX, OPEX, Total Cost of Ownership and payback to help make a complex challenge fundamentally easier to solve.

THE MAGAZINE

Mission Critical Magazine

march 2012 cover

2012 March-April

Mission Critical's latest issue is now available! Check it out!

TABLE OF CONTENTS SUBSCRIBE

PUE

Our Measured PUE is
See Poll Results Poll Archive

THE MISSION CRITICAL STORE

maintaining-mc.gif
Maintaining Mission Critical Systems in a 24/7 Environment, 2nd Edition

This book offers relevant insight into the Mission Critical Environment with an emphasis on business resiliency, data center efficiency, and green power technology.

More Products

Clear Seas Research

Clear Seas ResearchWith access to over one million professionals and more than 60 industry-specific publications,Clear Seas Research offers relevant insights from those who know your industry best. Let us customize a market research solution that exceeds your marketing goals.

Mission Critical Buyers Guide

Mission Critical's Buyers Guide: Find equipment and services for data center and emergency backup power applications. Click HERE to go to be taken to the MC Buyers Guide today!

STAY CONNECTED

facebook logo  LinkedInYouTube